It was issued by the standards council on july 26 2007 with an effective date of august.
Nec 2008 electrical panel clearance.
In every case the width depth and height of the working space around electrical equipment must allow all equipment doors or hinged panels to open at least 90 degrees.
Electrical panel clearance distances are given by the u s.
The purpose for the national electrical code is to provide a safe installation but article 110 is perhaps focused a little more on providing an installation that is safe for the installer and maintenance electrician so time spent in.
This clearance is different if the 480 volt electrical panel faces a wall where other electrical panels are located.
A clearance of at least 3 feet is required for equipment using 120 to 250 volts.
This electrical wiring articleseries discusses procedures for safe and effective visual inspection of residential electrical systems including electrical panels and other components when the inspection is conducted by trained building inspection professionals home inspectors.
And 3 minimum headroom.
The nec requires that there be a minimum of three feet of clearance in front of a 480 volt electrical panel.
A minimum of 30 inches of.
Three of these standards concern the box location clearance and space around the box and box height.
This clearance is measured for the live electrical parts or front of the electrical panel.
These standards set the minimum safety standards for panel boxes.
To ensure that an electrical panel can be accessed at all times during inspection maintenance or emergency osha has determined that the working space in front of the equipment must be at least 30 inches wide or the width of the equipment.
Clearance around an indoor electrical panel nec 110 26 clearance for conductor entering in panel nes 408 5 clearance between bare metal busbar in panel nes 408 5 clearance of outdoor electrical panel to fence wall nes 110 31 working space around indoor panel circuit board nes 110 34 clearance around an outdoor electrical panel nes.
Details are given here.
The national electric code nec includes the minimum standards for installing a circuit breaker panel box.
Nec specifying working distance.
Are you protecting yourself from electric shock and burns.
2 a 30 in wide working space in front of equipment operating at 600v or less.
National electrical code 2008 edition this edition of nfpa 70 national electrical code was prepared by the national electrical code committee and acted on by nfpa at its june association technical meeting held june 3 7 2007 in boston ma.
You re not if you fail to comply with the following three clearance requirements in sec.